Part Number Hot Search : 
00AXI 03DRL TE5544N H2106A01 B7220 74AC3 SA101 934512
Product Description
Full Text Search
 

To Download M-FIAM7M11 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Data Sheet
M-FIAM7
Features
* EMI filtering-MIL-STD-461E * Transient protection-MIL-STD-1275A/B/D, MIL-STD-704A-F and DO-160E * Environments-MIL-STD-810, MIL-STD-202 * Environmental stress screening * Low profile mounting options * Output power up to 130 W * Output current up to 10 A * Mini sized package * Inrush current limiting
Military COTS 28 Vin Filter Input Attenuator Module
Model Number: M-FIAM7M21*
Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm
Absolute Maximum Rating Product Highlights
The M-FIAM7 is a DC front-end module that provides EMI filtering and transient protection. The M-FIAM7 enables designers using Vicor's 28 V DC-DC V*I Chip modules to meet conducted emission/ conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-1275A/B/D, MIL-STD-704A-F and DO-160E. The M-FIAM7 accepts an input voltage of 14 - 50 Vdc and delivers output current up to 10 A. M-FIAM7 is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted onboard or inboard for height critical applications.
Parameter +In to -In Mounting torque Pin soldering temperature Rating 50 100 5 (0.57) 500 (260) 750 (390) Unit Vdc Vdc in-lbs F(C) F(C) Notes Continuous See Fig.1 6 each, #4-40 or M3 <5 sec; wave solder <7 sec; hand solder
Thermal Resistance and Capacity
Parameter Baseplate to sink flat, greased surface with thermal pad (P/N 20264) Baseplate to ambient Free convection 1000 LFM Min Typ 0.16 0.1 7.9 2.2 Max Unit C/Watt C/Watt C/Watt C/Watt
Compatible Products
* 28 V Input DC-DC V*I Chip modules.
MTBF per MIL-HDBK-217F (M-FIAM7M21)
Note: This product is not compatible with Maxi, Mini, Micro DC-DC converters.
Temperature 25C 50C 65C Environment Ground Benign: G.B. Naval Sheltered: N.S. Airborne Inhabited Cargo: A.I.C. MTBF 3,540 637 499 Unit 1,000 Hrs 1,000 Hrs 1,000 Hrs
Part Numbering*
M-FIAM7
Product
M
1= 2= S= N= F= G=
2
Pin Style Short Pin Long Pin Short ModuMate* Long ModuMate* Short RoHS Long RoHS
1
Baseplate 1 = Slotted 2 = Threaded 3 = Thru hole
Product Grade Temperatures (C) Grade Operating Storage M = -55 to +100 - 65 to +125 H = -40 to +100 -55 to +125
*Compatible with SurfMate and InMate socketing system.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 1 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS
(typical at TBP = 25C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter Input voltage Inrush limiting Min 14 Typ 28 Max 50 0.007 100 Transient immunity 250 70 80 Unit Vdc A/F Vdc Vdc Vdc Vdc 50 ms per MIL-STD-1275A/B/D, continuous operation 70 s per MIL-STD-1275B, continuous operation 20 ms per MIL-STD-704A, continuous operation 100 ms per DO-160E, Section 16, Power Input, Category Z Notes Continuous
OUTPUT SPECIFICATIONS
Parameter Output current Output power Efficiency Internal voltage drop External capacitance 330 1000 F 96 98 0.5 Min Typ Max 10 130 0.7 Unit A W % @10 A, 100C baseplate See illustration C1 on page 4 63 V Notes Over continuous input and temp. range (see Fig.4) Transient compliance over temp. range (see Fig.6)
CONTROL PIN SPECIFICATIONS
Parameter ON/OFF control Enable (ON) Disable (OFF) Min 0.0 4.0 Typ Max 1.0 5.50 Unit Vdc Vdc Notes Referenced to - Vout 100 k internal pull-up resistor
SAFETY SPECIFICATIONS
Parameter Dielectric withstand Min Typ 1,500 2,121 Max Vrms Vdc Unit Notes Input/Output to Base Input/Output to Base
EMI
Standard MIL-STD-461E Conducted emissions: Conducted susceptibility: Test Procedure CE101, CE102 CS101, CS114, CS115, CS116 Notes
GENERAL SPECIFICATIONS
Parameter Weight Warranty Min Typ Max 3.3 (94) 2 Unit Ounces (grams) Years Notes
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 2 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS (CONT.)
ENVIRONMENTAL QUALIFICATION
Altitude MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. Shock MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions. Humidity MIL-STD-810F, Method 507.4. Solder Test MIL-STD-202G, Method 208H, 8 hour aging.
ENVIRONMENTAL STRESS SCREENING
Parameter Operating temperature Storage temperature Temperature cycling* Ambient test @ 25C Power cycling burn-in Functional and parametric ATE tests Hi-Pot test Visual inspection Test data H-Grade -40C to +100C -55C to +125C 12 cycles -65C to +100C Yes 12 hours, 29 cycles -40C and +100C Yes Yes vicorpower.com M-Grade -55C to +100C -65C to +125C 12 cycles -65C to +100C Yes 24 hours, 58 cycles -55C and +100C Yes Yes vicorpower.com
Shut Down Time vs. Overvoltage
250 200
T (ms)
150 100 50 0 60 70 80 90 100 105 110 120
Vin (V)
Figure 1 - T = Time period before over-voltage protection. Vin = Input voltage (switching up from 28 Vdc)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Figure 2 - Conducted Noise; M-FIAM7 and MP028F036M12AL + MV036F120M010 DC-DC V*I Chip modules operating at 28 Vdc, 120 W.
M-FIAM7 Rev. 2.4 Page 3 of 6
Set your site on VICOR at vicorpower.com
Figure 3 - Transient Immunity; M-FIAM7 output response to an input transient.
Figure 4 - Inrush Limiting; Inrush current with 1000 F external capacitance.
M-FIAM7 EMI Compliance Only
600
M-FIAM7 EMI and MIL-STD-1275D Transient Compliance
140 130 120 110 100
(Normal Operation) (Transient 50 mS max.)
400 300 200 100 0 5 10 15 20 25 30 35 40 45 50
Output Power (W)
Output Power (W)
500
Safe Operating Area
Safe Operating Area
0 0 10 14 20 30 40 50 60 70 80 90 100 110
Input Voltage (VDC)
Input Voltage (VDC)
Figure 5 - M-FIAM7 EMI Compliance only
Figure 6 - M-FIAM7 EMI and MIL-STD-1275D Transient Compliance
C
- - ON OFF NC VC PC TM IL NC PR
C
VH SC SG OS NC CD +In +Out
Transorb P/N 19180-510 Input F1
EMI GND
C1
PRM-AL
+In +Out
MFIAM7
NC + NC +
TM VC PC
VTM K Ro
-Out
+Out
-In
-Out
-In
-Out
C Component Suggestions Recommended Fuse: (F1) 10 A (max), Bussmann ABC style Capacitance: (C1) 330 F (min), 1000 F (max); (C) 4700 pF
C
Figure 7 - Basic connection diagram with Transient, Surge Protection and Recommended Reverse Polarity Protection.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 4 of 6
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWINGS
Module Pins
No.
1 2 3 4 5 6 7 8 9
Function
+In No Connection Ground - In - Out ON/OFF No Connection No Connection +Out
Label
+ NC EMI/GND - - ON/OFF NC NC +
Figure 8 - Mechanical diagram
INBOARD SOLDER MOUNT SHORT PIN STYLE PCB THICKNESS 0.062 0.010 1,57 0,25 1.790** 45,47 PLATED THROUGH HOLE DIA 0.158 4,01 (7X) 0.094 0.003 2,39 0,08 0.164 0.003 4,16 0,08
ONBOARD SOLDER MOUNT LONG PIN STYLE 0.094 0.003 2,39 0,08 0.164 0.003 4,16 0,08
ALL MARKINGS THIS SURFACE
(2X)
R
0.06 (4X) 1,5
1
2
3
4
1.900* 48,26 48.26
1.575** 40,00
ALUMINUM BASEPLATE PINS STYLES SOLDER:TIN / LEAD HOT SOLDER DIPPED MODUMATE: GOLD PLATED COPPER RoHS: GOLD PLATED COPPER
9
8
7
6
5
0.400* 10,16 0.700* 17,78 1.000* 25,40 1.400* 35,56 0.003 0,08
0.43 10,9
0.53 13,5
0.195 4,95
* DENOTES TOL = ** PCB WINDOW
Figure 9 - PCB Mounting Specifications
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 5 of 6
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages.
Vicor's comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor's Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
3/09
Set your site on VICOR at vicorpower.com


▲Up To Search▲   

 
Price & Availability of M-FIAM7M11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X